DC Inverter Water Source Heat Pump
Heating & Cooling
R410a
Max. heating capacity: 238.7kw/h
- Features & Benefits
- Technical Specification
- Installation Sample
- Catalog & Inquiry
01
DC Inverter Technology
180° sine wave control, compressor soft start, automatic adjustment of variable frequency compressor speed, reasonable control of unit power input and heat output.
02
Multifunction Design, Flexible Application
Multifunction design and flexible application. Users can install the products according to their own needs. The modes of cooling, heating or domestic hot water are optional for different places.
03
Module Combination Design
This design is suitable for commercial, industrial, agricultural places with large hot water demands. One central controller is able to control 16 modular units.
04
Low Noise Running
A fully enclosed cabinet is specially designed for the compressor so that the running noise can be ketp inside and the noise of the whole unit can maintain very low.
05
Make Little Influence to Electricity Grid
No matter how many units you install, they can be started by turn, which makes very little influence to the electricity grid.
06
Stable Running and Easy Maintenance
Thanks to the separate installation, every unit works independently and if one of them breaks down, other units will not be afected. It is good for technicians to conduct maintenance.
| Model | 18 | 36 | 54 | 72 | 90 | 110 | |
|---|---|---|---|---|---|---|---|
| Minal cooling capacity (kw) | 70 | 140 | 210 | 280 | 350 | 420 | |
| Cooling input power (kw) | 12.5 | 25 | 37.5 | 50 | 62.5 | 75 | |
| Minal heating capacity (kw) | 56 | 112 | 168 | 224 | 280 | 336 | |
| Heating input power (kw) | 12 | 24 | 36 | 48 | 60 | 72 | |
| Supply voltage | 3N-380v-50Hz | ||||||
| Refrigerant | 410A | ||||||
| Water resistance (KPa) | 70 | ||||||
| Pipe diameter (DN) | 50 | 65 | 80 | 100 | 100 | 125 | |
| Evaporator | Frozen water volume (m³/h) | 12.1 | 24.1 | 36.3 | 48.4 | 60.5 | 60.5 |
| Well water volume (m³/h) | 12 | 24 | 36 | 48 | 60 | 72 | |
| Condenser | Hot water volume (m³/h) | 9.7 | 19.4 | 29.1 | 38.8 | 48.5 | 58.2 |
| Well water volume (m³/h) | 9.6 | 19.2 | 28.8 | 38.4 | 48 | 57.6 | |
| Dimensions (mm) | L | 1,050 | 1,350 | 1,650 | 1,950 | 2,250 | 2,550 |
| W | 1,150 | 1,150 | 1,150 | 1,150 | 1,150 | 1,150 | |
| H | 1,400 | 1,400 | 1,400 | 1,400 | 1,400 | 1,400 | |
Remarks:
1. Standard cooling conditions: chilled water inlet/outlet water temperature is 12℃/7℃, well water side inlet/outlet water temperature is 18℃/29℃.
2. Standard heating conditions: hot water inlet/outlet water temperature is 40/-℃, well water side inlet/outlet water temperature is 18/-℃.